3842 Diagnostic CONVERT not allowed if multiple users logged on.

Explanation:

DIAGNOSTIC CONVERT is used during the dictionary table conversion. It expects the current user to be DBC and the only user.

Generated By:

SYN modules.

For Whom:

The DBA.

Remedy:

Make sure there are no other users logged on.