SSH into the DSU vNode, get the output of /root/tvme/cmic_configuration.txt and save it for later.
# cat /root/tvme/cmic_configuration.txt
Sample output:
<Chassis idnum="###NEXT-AVAILABLE-CHASSIS-ID###"> <MEPlugin name="MEPlugin_Node_PFI"/> <IPv4 addr="203.0.113.17" netmask="255.255.254.0" type="public"/> </Chassis>
-
Log in to the Server Management Client, right-click on the CMIC node, and select Manage CMIC.
-
Save the current configuration file.
- Log in using the CMIC username and password.
- Navigate to .
- Click to save the current configuration into a local file as a backup.
-
Under the CMIC Configuration Editor, locate the system/collective/cabinet where you want to insert your DSU vNode, and append the output from Step 1 after the last chassis entry in that cabinet.
Modify ###NEXT-AVAILABLE-CHASSIS-ID### to the next available chassis ID in your environment. In our example below, the next available chassis ID is 5.
<System idnum="1"> <Collective idnum="1"> <MEPlugin name="MEPlugin_Collective"/> <Cabinet idnum="1"> <MEPlugin name="MEPlugin_Cab_Hybrid"/> <Chassis idnum="1" systemname="xxxx"> <MEPlugin name="MEPlugin_Teradata"> ... </Chassis> <Chassis idnum="2"> <MEPlugin name="MEPlugin_Node_PFI"/> ... </Chassis> <Chassis idnum="3"> <MEPlugin name="MEPlugin_Node_PFI"/> ... </Chassis> <Chassis idnum="4" type="cmic"> <MEPlugin name="MEPlugin_CMIC_PFI"/> ... </Chassis> <----- change ###NEXT-AVAILABLE-CHASSIS-ID### to 5 <Chassis idnum="5"> <MEPlugin name="MEPlugin_Node_PFI"/> <IPv4 addr="203.0.113.17" netmask="255.255.254.0" type="public"/> </Chassis> </Cabinet> </Collective> </System>
- After inserting the chassis entry for the DSU vNode, click to validate the syntax of the configuration file.
- If no errors are found, click to put the configuration to CMIC. Now the DSU vNode is added into CMIC and it should start showing up in Server Management Client.