Information to be sent to the database is placed by CLIv2 in a request buffer. CLIv2 allocates a single request buffer per session. The allocation takes place when the session is first established. DBCHCL automatically:
  • Expands the buffer if it is too small to hold the request being prepared.
  • Shrinks the buffer if Request-buffer-length is less than Current-request-buffer-length.

DBCHCL uses field values that the application has placed in the DBCAREA to determine which parcels to send to the database and what to put in them. The application does not see the request buffer.

How to Calculate Maximum Length

The maximum length (in bytes) needed for the request buffer can be calculated as follows:

maximum  Request-buffer-length  = 
   (14 if Request-processing-option = ‘P‘) +
   (4 + the maximum length of a request string) +
   (4 + the maximum length of using data,
      including indicator bytes if User Presence Bits 
      is set to ‘Y‘) +
   (length of parcels in any {DBCAIRX extension} +
   (6 for overhead)