Active Teradata Viewpoint Server Failure | Teradata Viewpoint - 16.20 - 16.50 - Active Teradata Viewpoint Server Failure - Teradata Viewpoint

Teradata® Viewpoint Installation, Configuration, and Upgrade Guide for Customers

Product
Teradata Viewpoint
Release Number
16.20
16.50
Release Date
July 2021
Content Type
Administration
Configuration
Installation
Publication ID
B035-2207-071K
Language
English (United States)

If the active Teradata Viewpoint server fails, the standby DCS detects that the active DCS and cache database are both down and logs an error to TVI and optionally sends out an email alert. The System Administrator can promote the standby cache database to the active cache database and send a notification to all Teradata Viewpoint portals so that they are automatically redirected to the new active cache database.

After the standby cache database is promoted, the System Administrator needs to set up a new standby cache database.

If the cluster is set up using the advanced configuration, stop the Teradata Viewpoint portal on the new active cache database server so that it continues to run on a dedicated machine.


Active Teradata Viewpoint Server Failure Recovery