The following example creates a user with a 10 percent skew limit for permanent space and a 20 percent skew limit for spool space:

CREATE USER Caspian AS PERM = 1e9 SKEW = 10 PERCENT, SPOOL = 2e9 SKEW = 20 PERCENT;

In the preceding example, if the system has 4 AMPs, each AMP has a limit of 250 MB of permanent space. With the permanent skew limit of 10 percent, any AMP can exceed the permanent space limit by 25 MB. An AMP may use up to 275 (250 + 25) MB of permanent space, if the total permanent space used by all AMPs does not go beyond the 1 GB global limit.

Similarly, each AMP has a limit of 500 MB of spool space. With the spool skew limit of 20 percent, any AMP can exceed the spool space limit by 100 MB. An AMP may use up to 600 (500 + 100) MB of spool space, if the total spool space used across all AMPs does not exceed the 2 GB global limit.