TDWMCreateArrivalRateMeter Syntax - Teradata VantageCloud Lake

Lake - Monitor Resources and Performance

Deployment
VantageCloud
Edition
Lake
Product
Teradata VantageCloud Lake
Release Number
Published
February 2025
ft:locale
en-US
ft:lastEdition
2025-11-21
dita:mapPath
wyu1683671641248.ditamap
dita:ditavalPath
pny1626732985837.ditaval
dita:id
wyu1683671641248
REPLACE PROCEDURE TDWM.TDWMCreateArrivalRateMeter (
  IN RulesetName TD_ANYTYPE,
  IN ArrivalRateName TD_ANYTYPE,
  IN Description TD_ANYTYPE,
  IN Attributes VARCHAR(20) CHARACTER SET LATIN,
  IN ReplaceOption CHAR(1) CHARACTER SET LATIN
)
  ...
;

Syntax Elements

RulesetName
Name of the ruleset in which to create the arrival rate meter. Use 'ALLRULESETS' to create the meter in all existing rulesets. Cannot be null and its length must be between 1 and 30.
ArrivalRateName
Name of the arrival rate meter to be created. The specified name must be unique among all existing TASM rules: throttles, arrival rate meters, workloads, filters, and so on. The name cannot be null and its length must be between 1 and 30 characters.
Description
Description of the arrival rate meter.
Attributes
See Workload Management User Guide for detailed descriptions of these attributes. Attributes can be combined.
  • Throttle type:
    • 'C' = collective
  • Disabling override:
    • 'D' = disable manual release or abort
  • Logging Only (warning):
    • 'L' = Only log a warning instead of delay or reject
ReplaceOption
  • 'Y' = Delete the specified arrival rate meter and recreate it. If the specified arrival rate meter does not exist, an error is returned.
  • 'N' = Create a new arrival rate meter. If the specified arrival rate meter exists, an error is returned.