Usage Notes - Parallel Data Pump

Teradata® Parallel Data Pump Reference

Product
Parallel Data Pump
Release Number
17.10
Published
June 2021
Language
English (United States)
Last Update
2021-07-01
dita:mapPath
oqw1608578437373.ditamap
dita:ditavalPath
ovd1619195504008.ditaval
dita:id
B035-3021
lifecycle
previous
Product Category
Teradata Tools and Utilities

Multiple tables can be targeted by a single Teradata TPump job.

If the script author is uncertain whether or not to use ROBUST restart logic, it is always safe to use the ROBUST ON parameter.

To ensure data integrity, the SERIALIZE parameter defaults to ON in the absence of an explicit value if there are upserts in the Teradata TPump job.

The statement rate per minute you set using the RATE keyword is also affected by the periodicity value. By default, Teradata TPump uses a periodicity value of four when enforcing the statement rate limit. You can adjust the periodicity rate from 1 to 1500 using a runtime parameter.

For example, if you set the statement rate at 1600 and the periodicity at 10, then the maximum number of statements processed is 160 (1600/10) statements every 6 (60/10) seconds.

A LOGOFF command entered after a BEGIN and before the matching END LOAD logs you off the Teradata TPump utility.