17.10 - CNSSET LINES - Advanced SQL Engine - Teradata Database

Teradata Vantageā„¢ - Database Utilities

Product
Advanced SQL Engine
Teradata Database
Release Number
17.10
Release Date
July 2021
Content Type
Configuration
Publication ID
B035-1102-171K
Language
English (United States)

Sets the number of lines that are saved from the output display area and sent to DBW after a reconnect with CNS.

Syntax

CNSGET LINES n

Syntax Elements

n
number of lines to be saved.
Valid values range from 2 to 72 lines.
The default is 10 lines.

Usage Notes

Teradata recommends setting large values (for example, 10 or more lines), unless the display of old input and output after a reconnect is a security concern.

To check the current number of lines set, issue the CNSGET command. For more information, see CNSGET.

Example: Setting the number of lines to be saved from the DBW display

In this example, the number of lines set to be queued on the system is 12.

cnsset lines 12

CNSSUPV: cns will save 12 lines per screen.