Hardware - Data Stream Architecture - Data Stream Utility

Data Stream Utility Installation, Configuration, and Upgrade Guide for Customers

Product
Data Stream Architecture
Data Stream Utility
Release Number
16.00
Published
November 2016
Language
English (United States)
Last Update
2018-04-17
dita:mapPath
lzp1474305417988.ditamap
dita:ditavalPath
3151_DSE_ICUCustomer_1600.ditaval.ditaval
dita:id
B035-3153
Product Category
Software
Teradata Tools and Utilities

pNode/Server: For example, Dell PowerEdge R720xd, Dell PowerEdge R730xd, HP Gen9 or similar with the following minimum resources:

Item Resource
CPU 4
Memory 16 GB
Storage Datastore must be able to fit a 500 GB VMware image.

The OS drive uses approximately 200 GB of space and the DSU repository uses approximately 300 GB of space

Separate Physical Networks 1 – public

2 – CMIC (optional)

1 – DSU (10 GB network, optional)

Special Requirements

vCenter allows for distributed and local virtual switches. This version of vCenter only supports local virtual switches, so each ESXi host must have local virtual switches for the public network, and any optional CMIC or DSU networks.

The DSU virtual switches must have MTU values of 9000 for optimum performance.
  • For best performance, all virtual switches must be on their own physical network.
  • For low performance systems (for example, development or test), the virtual adapters can be placed on the same physical network, recognizing that performance will be reduced with the shared bandwidth.

    With the exceptions of the public and CMIC subnets, using an MTU value of 9000 may cause problems on subnets that are using an MTU of a different size.

All virtual instances require static IPs.