  1. Return to Server Management Client.
  2. In the Locator LED Enabled window, click Disable.
  3. When the Disable Locator LED Success window appears, click OK.
  4. Add a comment to the summary alert:
    1. In the Server Management Client window, select the Summary Alerts tab. A list of summary alerts appears.
    2. Locate the appropriate summary alert.
    3. On the right side, click the three-bar icon.
    4. Select Add Comment. The Comments window appears.
    5. You must add entries in both the Author and the Comment box.
    6. Click Submit. The comment is attached to the summary alert.
  5. Clear the summary alert:
    1. Click the Summary Alerts tab.
    2. On the right side of the summary alert, click the three-bar icon.
    3. Click Clear Summary Alert.
  6. Close the maintenance window:
    1. In the Server Management Client window, click the Overview tab.
    2. In the Active Maintenance Windows, locate the relevant maintenance window.
    3. On the right side of the column, click the trash can icon.
    4. In the Maintenance Window, click Delete.
  7. Log off Server Management Client.