Business Continuity Manager re-synchronizes tables that are out of sync.
  1. Use one of the following methods to re-synchronize an unrecoverable table.
    Method Steps
    Business Continuity Manager UI
    1. From the Business Continuity Manager UI, select OBJECTS or DATABASES.
    2. Select an object or a database to synchronize.
    3. Do one of the following:
      • In the object data window, select Sync.
      • In the database data window, select Sync Database.
    bcmadmin
    • bcmadmin> help object resync;
      Command: OBJECT RESYNC <tablename>|id:<object id> FROM <tdpid1> TO <tdpid2> [TIMEOUT '<timeout (seconds)>']
      Description: Synchronizes the specified table from the source system to the destination system 
      
      bcmdmin> OBJECT RESYNC table1 FROM db1 TO db2 TIMEOUT 600;
      
    • bcmadmin> help database resync;
      Command: DATABASE RESYNC <database name FROM <tdpid1> TO <tdpid2> [TIMEOUT '<timeout (seconds)>']
      Description: Synchronizes all the tables in the specified database from the source system to the destination system 
      