Manual In-Doubt Resolution - Teradata Tools and Utilities

Teradata® Call-Level Interface Version 2 Reference for Mainframe-Attached Systems

Product
Teradata Tools and Utilities
Release Number
17.00
Published
June 2020
Language
English (United States)
Last Update
2020-06-18
dita:mapPath
lvt1544831946862.ditamap
dita:ditavalPath
obe1474387269547.ditaval
dita:id
B035-2417
lifecycle
previous
Product Category
Teradata Tools and Utilities

When automatic in-doubt resolution is unavailable or unsuccessful, it may be necessary to manually resolve the in-doubt sessions. This is because the in-doubt sessions could be holding locks on database objects that block the progress of other work that is executing against that database.

Incorrect use of manual in-doubt resolution can damage the database.
You can use any of the following interfaces to accomplish manual in-doubt resolution:
  • The TDP commands DISPLAY INDOUBT, COMMIT, and ROLLBACK
  • The TPCCONS utility on the operator‘s console
  • A CLIv2 program to log on to the Resolver Base Module (RBM) with the CLIv2 Run parcel and resolving the sessions using the TPCCONS commands
  • Using CLIv2 applications to issue TDP commands using the CMD function (for more information on the CMD function, see DBCHCL.

For more information on Two-phase commit in-doubt resolution, see the following documents:

  • IBM CICS Interface for Teradata® Reference, B035-2448
  • IBM IMS Interface for Teradata® Reference, (B035-2447)
  • IBM Database 2 V1 R1-CICS/VS Interface Guide, document number GG24-1632-00, from IBM