Refresh-cached-data - Call-Level Interface Version 2

Teradata Call-Level Interface Version 2 Reference for Mainframe-Attached Systems

Product
Call-Level Interface Version 2
Release Number
16.10
Published
May 2017
Language
English (United States)
Last Update
2018-05-07
dita:mapPath
jen1488824663137.ditamap
dita:ditavalPath
Audience_PDF_include.ditaval
dita:id
B035-2417
lifecycle
previous
Product Category
Teradata Tools and Utilities

Refresh-cached-data specifies whether response data previously processed by CLIv2 can be re-used or must be reread from the Teradata Database.

This option would not be used by a normal application. It is intended only for diagnostic use.

Refresh-cached-data exists only when DBCHINI had been called for a DBCAREA with Total-length set to at least 640 (that is, the returned DBCAREA Level value is at least 1). For a smaller DBCAREA, Refresh-cached-data is ignored.

In this language... The variable name for Refresh-cached-data is...
COBOL DBRIRCD
PL/I DBRIRCD
C, C++ dbriRCD
IBM Assembler DBRIRCD
This routine... Does this for Refresh-cached-data...
DBCHINI writes
DBCHCL reads (RSUP; IRQ; IWPF)
Refresh-cached-data is used by... To...
applications write

One of the following values may be set before initiating a request:

If the previously processed response... Then set Refresh-cached-data to...
indicates that response data previously processed by CLIv2 can be re-used (default) 'N'
indicates that response data previously processed by CLIv2 must be reread from the Teradata Database. 'Y'

Use mnemonics for the codes. Mnemonics are provided in the language definition file for the DBCAREA.