Verify Failover Configuration | Data Mover - Verifying Failover Configuration - Teradata Data Mover

Teradata® Data Mover Installation, Configuration, and Upgrade Guide for Customers

Product
Teradata Data Mover
Release Number
17.20
Published
September 2022
Language
English (United States)
Last Update
2022-09-26
dita:mapPath
lzn1650878358910.ditamap
dita:ditavalPath
stp1591127384938.ditaval
dita:id
B035-4102
lifecycle
previous
Product Category
Analytical Ecosystem
  1. On the designated-active server, verify that all Data Mover agents are listed in the output:
    datamove list_agents
  2. On the designated-standby, verify the daemon is not running:
    /etc/init.d/dmdaemon status
  3. On the designated-standby, verify the REST service is not running:
    /etc/init.d/tdmrest status
  4. On the designated-standby, verify the ActiveMQ is not running:
    /etc/init.d/tdactivemq status
  5. Run a Data Mover TPT job.
    1. Set max_agents_per_task to the number of Data Mover agents in the cluster.
    2. Set data_streams to a value greater than or equal to max_agents_per_task.
    3. Check the job status to verify that the job ran successfully and that all Data Mover agents are in use.