Source and Target Systems | Teradata Data Mover - Source and Target Systems - Teradata Data Mover

Teradata® Data Mover User Guide

Product
Teradata Data Mover
Release Number
17.12
Published
January 2022
Language
English (United States)
Last Update
2022-01-18
dita:mapPath
ptl1635805434108.ditamap
dita:ditavalPath
mpm1591127278842.ditaval
dita:id
B035-4101
lifecycle
previous
Product Category
Analytical Ecosystem
  • The source and target systems must be 16.20.53.07 or above
  • The source system must enable backup for IR:
    • Set GDO 553 – EnableBackupsforIncrementalRestore > 0

      Enable BackupsforIncrementalRestore for object level

      Enable BackupsforIncrementalRestore for whole system

    • Restart bardsmain on the target database cnsterm 6:

      Stop bardsmain: cnsterm 6 start bardsmain -s

      Start bardsmain: cnsterm 6 start bardsmain

  • The target system must enable Incremental Restore (IR)

    GDO 555 - IgnoreIncrementalRestoreState = false

    The GDO flag is set to false by default and no further action is needed.

    If the flag has been modified to "true" previously, run dsc reset_ir_target_system command to clear the flag so IR is re-enabled.

Incremental Copy is supported in the following versions:
Source SQL-E Version Target SQL-E Version
17.10.00.00 17.05.00.00 17.00.00.00 16.20.53.07+
17.10.00.00 Yes _ _ _
17.05.00.00 Yes Yes _ _
17.00.00.00 Yes Yes Yes _
16.20.53.07+ Yes Yes (must be 17.05.05.03+) _ Yes