16.10 - MLOADXUtilityLimits - Teradata Database

Teradata Database Utilities

Product
Teradata Database
Release Number
16.10
Published
June 2017
Language
English (United States)
Last Update
2018-04-26
dita:mapPath
zll1480972831047.ditamap
dita:ditavalPath
changebar_rev_16_10_exclude_audience_ie.ditaval
dita:id
vkz1472241255652

Purpose

Determines whether MultiLoad Extended Protocol (MLOADX) concurrent task and AWT limits are specific to MLOADX jobs or are shared with other load utilities (FastLoad, MultiLoad, and FastExport).

Field Group

General

Valid Settings

Setting Effect
TRUE MLOADX concurrent task and AWT limits are determined by the values of DBS Control fields MaxMLOADXTasks and MaxMLOADXAWT, instead of by the values of MaxLoadTasks and MaxLoadAWT.
FALSE MLOADX shares the concurrent task and AWT limits of FastLoad, MultiLoad, and FastExport, which are determined by the values of DBS Control fields MaxLoadTasks and MaxLoadAWT.

Default

FALSE

Changes Take Effect

After the DBS Control record has been written.

Usage Notes

This field is ignored if the throttles category set in the Teradata Viewpoint Workload Designer portlet is enabled.

Related Topics

For more information on... See...
Load utilities (MultiLoad, FastLoad, FastExport, and Teradata Parallel Transporter) Teradata MultiLoad Reference, Teradata FastLoad Reference, Teradata FastExport Reference, Teradata Parallel Transporter User Guide