Purpose
Determines whether MultiLoad Extended Protocol (MLOADX) concurrent task and AWT limits are specific to MLOADX jobs or are shared with other load utilities (FastLoad, MultiLoad, and FastExport).
Field Group
General
Valid Settings
Setting | Effect |
---|---|
TRUE | MLOADX concurrent task and AWT limits are determined by the values of DBS Control fields MaxMLOADXTasks and MaxMLOADXAWT, instead of by the values of MaxLoadTasks and MaxLoadAWT. |
FALSE | MLOADX shares the concurrent task and AWT limits of FastLoad, MultiLoad, and FastExport, which are determined by the values of DBS Control fields MaxLoadTasks and MaxLoadAWT. |
Default
FALSE
Changes Take Effect
After the DBS Control record has been written.
Usage Notes
This field is ignored if the throttles category set in the Teradata Viewpoint Workload Designer portlet is enabled.
Related Topics
For more information on... | See... |
---|---|
Load utilities (MultiLoad, FastLoad, FastExport, and Teradata Parallel Transporter) | Teradata MultiLoad Reference, Teradata FastLoad Reference, Teradata FastExport Reference, Teradata Parallel Transporter User Guide |