Purpose
Specifies the number of MultiLoad Extended Protocol (MLOADX) tasks (jobs) that are allowed to run concurrently on Teradata Database.
Throttle rules for load utility concurrency set in the Teradata Viewpoint Workload Designer portlet override the MaxMLOADXTasks setting.
Field Group
General
Valid Range
0 through 120
Default
30 tasks
Changes Take Effect
After the DBS Control Record has been written.
Usage Notes
This field is enforced only when MLOADXUtilityLimits is set to TRUE. In these cases, the setting of MaxLoadTasks does not apply to MLOADX jobs.
This field is ignored if the throttles category set in the Teradata Viewpoint Workload Designer portlet is enabled.
Related Topics
For more information on... | See... |
---|---|
Load utilities (MultiLoad, FastLoad, FastExport, and Teradata Parallel Transporter) | Teradata MultiLoad Reference, Teradata FastLoad Reference, Teradata FastExport Reference, Teradata Parallel Transporter User Guide. |