16.10 - Prerequisites - Teradata Database

Teradata Database Utilities

Product
Teradata Database
Release Number
16.10
Published
June 2017
Language
English (United States)
Last Update
2018-04-26
dita:mapPath
zll1480972831047.ditamap
dita:ditavalPath
changebar_rev_16_10_exclude_audience_ie.ditaval

You can run rcvmanager only while the Teradata Database is in one of the following states:

  • Logon
  • Logon/quiet
  • Logoff
  • Logoff/quiet
  • Startup (if the Teradata Database system has completed voting for transaction recovery)

If you attempt to start rcvmanager while the Teradata Database system is not in one of the allowable states, the utility displays the following error information and terminates:

RCVMANAGER can only be run when the system is in the “LOGON” or “LOGOFF” state or if the system is in the “STARTUP” state and has completed voting for transaction recovery. The current system is not in one of these allowable states thus preventing RCVMANAGER from operating.
RCVMANAGER terminated.