The following table lists sense bytes 0 and 1, along with the corresponding device status byte (in hexadecimal) as returned in the CSW for devices of CPs that do not require the CCU operand on the START command:
Sense Byte | Status Byte | Description | |
---|---|---|---|
0 | 1 | ||
10 | 01 | 0E | CIC hardware error |
08 | 05 | 0E | Bus/Tag in driver fault |
80 | 06 | 0E | Illegal field id for dev 0 |
80 | 07 | 0E | Message header size error for dev 0 |
80 | 08 | 0E | Message count error for dev 0 |
80 | 09 | 0E | Message size error for dev 0 |
80 | 0C | 0E | Odd byte xfer for dev 0 |
80 | 0D | 0E | Input Queue empty for dev 0 write |
80 | 0E | 0E | Rewind for dev 0 without a Writekey |
80 | 10 | 0E | Dev 1 read stopped before all the data was transferred |
80 | 11 | 0E | Two consecutive dev 0 Writekeys |
80 | 14 | 0E | Unrecognized command byte during Initial Selection sequence |
20 | 19 | 0E | Bad parity on Command byte during Initial Selection or following a Write operation |
10 | 28 | 0D | CP did not respond to CIC interrupt in allotted time (1 second) |
00 | 30 | 22 | IOP Startup byte |
00 | 33 | 85 | The CIC has gone from OFFLINE to ONLINE. |
80 | 39 | 0E | Write operation exceeded maximum CIC local buffer length |
80 | 43 | 0E | WriteCount specified a max block size too small for the database |
80 | 44 | 0E | WriteKey block size greater than maximum allowed |