The behavior of database-generated applications in the event of a node resetting depends on the:
  • Crash notification setting
  • Type of node on which PP2 is running

Application Behavior on a Resetting Node

If a PP2-generated application is running on a resetting node, PP2 aborts. Restart the application after the node resets.

This is equivalent to the situation where a utility or application is initiated on an external client that fails.

Setting Crash Notification

Specify crash notification behavior with the SET CRASH statement, which sets the following wait_across_crash (WAC) and tell_about_crash (TAC) options:

Specified Option WAC Setting TAC Setting
WAIT_NOTELL ‘Y’ ‘N’
NOWAIT_TELL ‘N’ ‘Y’
The default settings for these options are:
  • wait_across_crash (WAC) = ‘Y’
  • tell_about_crash (TAC) = ‘N’

For information on GET CRASH and SET CRASH, see Teradata Vantage™ - SQL Stored Procedures and Embedded SQL , B035-1148 .

Application Response When WAC is Set to Y and TAC is Set to N

The following table describes the behavior of PP2-generated applications when a node resets and WAC = ‘Y’ and TAC = ‘N’.

Type of Node or Client PP2-Generated Application Runs On Action Taken
  • Non-Resetting node
  • LAN-attached client
  • Mainframe-attached client
PP2 reconnects its session and returns one of the following error codes from the server. The PP2-generated application takes action appropriate to the error condition:
  Code Number Description
Error 2825 No record of the last request was found after database restart.
Error 2826 Request completed but all output was lost due to database restart.
Error 2828 Request was rolled back during system recovery
Error 3120 The request is aborted because of a database recovery.

Application Response When WAC is Set to N and TAC is Set to Y

The following table describes the behavior of PP2-generated applications when a node resets and WAC = 'N' and TAC = 'Y'.

Type of Node or Client PP2-Generated Application Runs On Actions Taken
  • Non-Resetting node
  • LAN-attached client
  • Mainframe-attached client
PP2 immediately disconnects the session. The application receives one of the following CLI error codes:
  Code Number Description
Error 219(EM_DBC_CRASH_B) Server connection lost (network or server problem).
Error 220(EM_DBC_CRASH_A) Server connection lost (network or server problem).