Resolved issues track corrections and updates to Teradata Tools and Utilities software and to documentation affected by the updates.
Issue | Description |
---|---|
ODBC-235 | The ODBC Driver for Teradata now returns a proper SQLState for conversions from SQL_C_TYPE_DATE to SQL_CHAR when an invalid date literal is used |
ODBC-538 | Fix to return proper SQLStates for conversions SQL_C_TYPE_DATE to SQL_TYPE_TIMESTAMP/SQL_TYPE_DATE |
ODBC-796 | Problem in conversions from SQL_C_UTINYINT and SQL_C_UTINYINT to Single Field Interval types has been resolved |
ODBC-809 | Catalog functions now return the proper errors when Schema, Table or Column Name = NULL and NameLength > 1 |
ODBC-829 | ODBC Scalar function timestampadd() gives correct results |
ODBC-832 | NULL value conversions from SQL_C_SBIGINT and SQL_C_UBIGINT to numeric destinations has been resolved |
ODBC-881 | The error code returned with conversions from the _UnsignedNumeric type to the Single Field Interval type has been resolved |
ODBC-922 | When using the Teradata SQL Assistant application with the ODBC Driver for Teradata, it now displays function types from tvm.tablekind of A, B, R and S |
ODBC-1377 | SQLFetch now returns SQL_NO_DATA_FOUND return code on subsequent SQLFetch calls at the end of result-set |
ODBC-1419 | Diagnostic messages are now ranked per the ODBC specification |
ODBC-1528 | SQLExecDirect and SQLExecute connection reset issues surface in the ODBC Driver for Teradata with conversion of parameters to SQL LOB types has been resolved |
ODBC-1555 | Fixed the multi-threaded connection core-dumps inside the driver |
ODBC-1569 | SQLGetDescField now returns correct SQL_DESC_CONCISE_TYPE values for Date, Time, and TimeStamp |
ODBC-1598 | Fix conversions from SQL_C_S/TINYINT/SQL_C_S/SHORT/SQL_C_S/LONG to Single Field Interval Types |
ODBC-1682 | The SQLProcedureColumns() now returns expected results |
ODBC-1717 | The NULLABLE column of catalog functions SQLColumns, SQLTables, and SQLGetTypeInfo has been resolved |
ODBC-3049 | Inconsistent results of SQLTables has been resolved |
ODBC-3117 | The user can now insert NULL values for the SQL_DECIMAL and SQL_NUMERIC parameters |
ODBC-3127 | SQLGetConnectAttr now returns the correct sqlstate for SQL_ATTR_SIMULATE_CURSOR |
ODBC-3176 | The invalid precision descriptor consistency check for floating point types has been resolved |
ODBC-3180 | Retrieval of fractional values of Interval types has been resolved |
ODBC-3260 | The SQLGetDescField attributes SQL_DESC_PARAMETER_TYPE and SQL_DESC_UNNAMED have been resolved |
ODBC-3265 | The ODBC Driver for Teradata no longer fails when the default DSN with an undefined DSN is given |
ODBC-3324 | The ODBC Driver for Teradata now insert character and binary (non-LOB) data in parts using SQLPutData |
ODBC-3536 | The ODBC Driver for Teradata now accepts connection-string values enclosed in brackets {} |
ODBC-4732 | An incorrect statement state after a SQLFetch in the ODBC 2.x specification has been resolved |
ODBC-4811 | Providing an invalid attribute with NULL buffer and BufferLength < 1 to SQLGetStmtAttr has been resolved |
ODBC-4969 | Conversion of values greater than 2147483647 bytes to SQL_C_ULONG buffers has been resolved |
ODBC-4999 | SQLGetDiagField for diagnostic fields SQL_DIAG_DYNAMIC_FUNCTION and SQL_DIAG_DYNAMIC_FUNCTION_CODE has been resolved |
ODBC-5058 | On Solaris the pkgadd function now updates the "tdodbc" package to the installed package list even if the install process fails on a NFS file system |
ODBC-6577 | The insertion of parameter arrays with multi insert has been resolved |
ODBC-6668 | SQLColumns has been fixed to return the correct precision for INTERVAL columns |
ODBC-7809 | The SQLTables TableType filter now functions properly |
ODBC-7877 | Conversions from SQL_INTERVAL_SECOND to SQL C integer types has been resolved |
ODBC-7973 | SQLState conversions from SQL_C_CHAR to SQL_TYPE_TIMESTAMP for invalid strings has been resolved |
ODBC-9951 | Retrievals of valid numeric literals to DECIMAL has been resolved |
ODBC-9970 | When an insufficient BufferLength is given in the connection string, SQLBrowseConnect no longer returns SQL_SUCCESS_WITH_INFO |
ODBC-10023 | The SqlTypes array loop now continues only until the last location |
ODBC-10936 | SQLPrimaryKeys now returns no key if the session character set is UTF-8 and the IANAAppCodePage=106 |
ODBC-11341 | A long SQL SELECT no longer gets a code of "-1" on SQLDescribeCol when using the ODBC Driver for Teradata with TD 14.10 |
ODBC-11378 | MS Access queries using date parameters no longer fail |
ODBC-11469 | Conversions from SQL_C_UBIGINT to SQL_FLOAT with values larger than max BIGINT have been resolved |
ODBC-11554 | ODBC DSN setup now defaults to ASCII if the session-character-set name is very long |
ODBC-12273 | A core dump issue has been resolved when a parameter array insert is bound to LOB columns |
ODBC-12284 | ODBC JSON datatype now return the same integer values as a CLOB column defined with the exact same size as the JSON column with SQLColAttributes when using attributes SQL_COLUMN_EXPORT_WIDTH and SQL_COLUMN_EXPORT_WIDTH_ADJ |
ODBC-12405 | The parser now preserves the ON COMMIT clause when creating volatile and global temporary tables |
ODBC-12548 | Conversions from SQL CHAR to C INTERVALs when the source column has trailing spaces has been resolved |
ODBC-12638 | The "unresolved code symbol alloca" for large nested SQL requests on HP-UX is now resolved |
ODBC-12647 | SQLExecute has been resolved when the last value in an array of parameters is NULL |
ODBC-12999 | The retrieval of fractional seconds in INTERVAL_DAY_TO_SECONDS and INTERVAL_MINUTE_TO_SECONDS has been resolved |
ODBC-13161 | The ODBC Driver for Teradata now scans for special characters in the connection string attribute-value from a connect dialog and returns them in braces |
ODBC-14640 | Fixed Garbled messages displayed by Driver on Japanese machines |
ODBC-15017 | ODBC Driver fails to connect when the username or password contains a comma. |
ODBC-15049 | In a parameterised array insert, SQL_ATTR_PARAMS_PROCESSED_PTR is updated incorrectly when SLOB is enabled |
ODBC-15582 | "ENABLELEGACYPARSER=Y|N" can now be used as a connection string option as well |
ODBC-15794 | Parameterized LOB NULL insert fails on SLOB supported database when table has two or more LOB columns |
ODBC-15857 | Parameterised array INSERT on LOB columns with rows mix of null & non-null leads to DBS error |
ODBC-16245 | Driver now strips out the LineFeed Character from SQL Statements |