Performing an IPL - Teradata Tools and Utilities

Teradata® Tools and Utilities for IBM z/OS Installation Guide - Teradata Director Program - 17.20

Product
Teradata Tools and Utilities
Release Number
17.20
Published
September 2022
ft:locale
en-US
ft:lastEdition
2022-10-11
dita:mapPath
hph1662964204836.ditamap
dita:ditavalPath
ppr1662968569655.ditaval
dita:id
B035-3514
lifecycle
previous
Product Category
Teradata Tools and Utilities
After you have completed the previous steps, you may perform this step at any time before or after you complete the installation of the Teradata software.
The Copying Host Communication Interface (HCI) Modules task requires an Initial Program Load (IPL) or issue the MVS SETPROG LPA or a SET PROG= command to refresh the Link Pack Area. It is recommended that an IPL only be performed once, and not be performed until the Copying Host Communication Interface (HCI) Modules procedure is performed.
  1. [Optional] If changes were made to IEASVCxx and the DYNAMIC operand will not be used on the TDP INITIAL IACMODE SVC command, perform an IPL.
  2. Perform an IPL or issue the MVS SETSSI command to effect the changes to IEFSSNxx.
  3. Perform an IPL or issue the MVS SET SCH= command to effect the changes to SCHEDxx.
  4. Perform an IPL, issue the MVS SET PROG=, or issue the MVS SETPROG APF command to effect the changes to PROGxx.