2PC Processing - Teradata Tools and Utilities

Teradata Tools and Utilities for IBM z/OS Installation Guide

Product
Teradata Tools and Utilities
Release Number
15.10
Published
August 2016
Language
English (United States)
Last Update
2018-06-05
dita:mapPath
PDF_Installation_ZOS_1600.ditamap
dita:ditavalPath
ft:empty
dita:id
B035-3128
lifecycle
previous
Product Category
Teradata Tools and Utilities
  1. For automatic in-doubt resolution for 2PC processing, configure the CICS system to be able to do a warm start.
  2. Delete or comment out the Teradata Director Program command, DISABLE IRF, in the TDPPARM data set.This is described in TDPPARM Settings for 2PC Processing. After the DISABLE IRF command is eliminated, the two TDP-internal sessions necessary for 2PC processing are logged on automatically upon TDP startup.
  3. Authorize CICS to Teradata Director Program in the TDPPARM data set.
  4. Create new entries in the TDPPARM data set for each CICS system that uses 2PC protocol. The entries, which authorize each CICS system to Teradata Director Program, have the following form:
    AUTHORIZ cicsjob RESOLVE
    where cicsjob specifies the jobname for the CICS system.