After you have completed the previous steps, you may perform this step at any time before or after you complete the installation of the Teradata software.
The Copying Host Communication Interface (HCI) Modules task requires an Initial Program Load (IPL) or issue the MVS SETPROG LPA or a SET PROG= command to refresh the Link Pack Area. It is recommended that an IPL only be performed once, and not be performed until the Copying Host Communication Interface (HCI) Modules procedure is performed.
  1. [Optional] If changes were made to IEASVCxx and the DYNAMIC operand will not be used on the TDP INITIAL IACMODE SVC command, perform an IPL.
  2. Perform an IPL or issue the MVS SETSSI command to effect the changes to IEFSSNxx.
  3. Perform an IPL or issue the MVS SET SCH= command to effect the changes to SCHEDxx.
  4. Perform an IPL, issue the MVS SET PROG=, or issue the MVS SETPROG APF command to effect the changes to PROGxx.