SEQUENCER Configuration Parameters - Teradata Unity

Teradata® Unity™ User Guide

Product
Teradata Unity
Release Number
16.50
Published
January 2020
Language
English (United States)
Last Update
2020-02-04
dita:mapPath
frp1571162435023.ditamap
dita:ditavalPath
ft:empty
dita:id
B035-2520
lifecycle
previous
Product Category
Analytical Ecosystem
The following parameters are available at the Sequencer level.
Parameter Default Valid Values Scope Description
disableEMevents 0 0,1 global Use to disable Ecosystem Manager alerts and events. Set to 1 to stop sending TMSM/EM events and alerts to Ecosystem Manager.
ExportMaxJobs 5 0 to infinity, inclusive   Sets the maximum number of export jobs allowed on a Unity system.
LoadRequestTimeout 90 seconds

Value type: Integer

Allowed value range: greater than or equal to 5

Only for sequencer Sets the timeout length for a load request from the Sequencer. Use to prevent timeouts for the load request from the active sequencer, for example, when the two Unity regions have significant network delays.