Teradata Database Message 1170 - 1170 - Analytics Database - Teradata Vantage
Teradata® VantageCloud Lake - Analytics Database Messages
- Edition
- Lake
- Product
- Analytics Database
- Teradata Vantage
- Published
- October 2022
- Language
- English (United States)
- Last Update
- 2024-02-26
- dita:mapPath
- tzr1629746512312.ditamap
- dita:ditavalPath
- ft:empty
- dita:id
- vza1585613049811
- lifecycle
- latest
- Product Category
- Teradata® Vantage™
- Message
- The system has/had down amp(s) and the table being dumped/restored has no fallback. Data might be lost.
- Explanation
- One of these cases is the reason: 1)The system has down amp(s) and the table being dumped has no fallback. 2)The system has no amp(s) and we are restoring a table from case 1. 3)The system has down amp(s) and we are restoring a table that had no fallback.
- Generated By
- BAR.
- For Whom
- End user.
- Notes
- None.
- Remedy
- For each case, accordingly: 1) No remedy than bringing back amp(s) or changing its protection 2) Exclude it to save its data at the destination 3) Bring amp(s) back up, then it can be restored