- Message
- ROLLBACK/ROLLFORWARD table specifications are invalid.
- Explanation
- A ROLLBACK or ROLLFORWARD statement has been submitted for which the specified table(s) either would require use of two different journals or would not result in any recovery being performed. If multiple individual tables are specified then they all must use the same journal table. If a single table is specified then it must have a journal option and if a processor list is included in the statement then the table must not have the fallback option.
- Generated By
- OPT modules.
- For Whom
- End User.
- Notes
- None
- Remedy
- Do separate ROLLBACK/ROLLFORWARD operations for tables using different Journals, or do not request recovery of a single table without the journal option or do not request specific processor recovery of a single table with the fallback option.