Message
Sort attempted to generate an invalid row uniq value.
Explanation
The sort routine generated two rows with the same row-id at a time when it was specifically generating artificial uniq values for the rows.
Generated By
File System
For Whom
Field Engineer
Notes
This indicates a File System software error.
Remedy
Contact a field engineer.