Teradata Database Message 7516 - 7516 - Analytics Database - Teradata Vantage

Teradata® VantageCloud Lake - Analytics Database Messages

Edition
Lake
Product
Analytics Database
Teradata Vantage
Published
October 2022
Language
English (United States)
Last Update
2024-02-26
dita:mapPath
tzr1629746512312.ditamap
dita:ditavalPath
ft:empty
dita:id
vza1585613049811
lifecycle
latest
Product Category
Teradata® Vantage™
Message
Stale object identifier.
Explanation
This error is returned when a reference to a large object value cannot be resolved because the object was deleted or modified after the reference was generated.
Generated By
The large object access routines
For Whom
Customer.
Notes
This error can occur in the following situations: 1. A query referenced a large object under an access lock while another transaction modified the same object. 2. A query returned a non-static locator, which was used in a subsequent query after committing the original transaction, but the object was modified in the interval between the end of the original transaction and the time the locator was dereferenced.
Remedy
In the first situation, resubmit the query that failed. If the error occurs too frequently, consider using a read lock. In the second situation, consider using static locators to preclude occurrences of this error.