Teradata Database Message 9013 - 9013 - Analytics Database - Teradata Vantage

Teradata® VantageCloud Lake - Analytics Database Messages

Edition
Lake
Product
Analytics Database
Teradata Vantage
Published
October 2022
Language
English (United States)
Last Update
2024-02-26
dita:mapPath
tzr1629746512312.ditamap
dita:ditavalPath
ft:empty
dita:id
vza1585613049811
lifecycle
latest
Product Category
Teradata® Vantage™
Message
Invalid alternate parcel header sent by host.
Explanation
This error is returned for following cases: 1) ARCMAIN needs to user the Alternate Parcel Header (APH) in 13.1. If no HUT request is sent by client using the APH, this error is returned. 2) The alternate parcel header has 2 reserved bytes following the parcel flavor that must be set to 0. If this is a non zero value, this error is reported.
Generated By
HUT subsystem.
For Whom
Support Representative.
Notes
None
Remedy
Ensure that the ARCMAIN software is compatible with the DBS ARCMAIN must submit all requests using the alternate parcel header format or handle the error code received.