Message
No PE for CUA 0x%x in HGID %d
Explanation
No PE is available to start the specified channel unit adapter (CUA). Either there is no online PE with the same host group ID (hgid) as is specified for the CUA in the vconfig GDO, or the node selected to start the CUA is already starting 64 other CUAs.
Generated By
toshostenable service.
For Whom
System Support Representative.
Notes
None
Remedy
This message is only a warning, and appears only on the control node. Teradata runs normally except that no connections are available through the specified channel. This is expected when the node hosting the channel is down or when its associated PE is offline. A TPA restart is required restore the channel after its node reboots or its PE is ready to come back online.