RSS ecountered an anomaly in counting %s; expected %d but found %d.
Explanation
During tpa initialization, the Resource Sampling System tallies the storage device list, and subsequently re-traverses the list building an internal table. On this re-traversal, the number of entries of interest had increased; however, RSS was able to handle the increase without error. This usually happens because some function like findit is still adding logical devices while tpainit is running.
Generated By
PDE resource usage monitoring.
For Whom
System Administrator, System Support Representative.
Notes
RSS error messages are normally warnings only, but the calling routine may be coded to terminate after the error message is displayed.
Remedy
If the above explanation seems to fit the case, no remedy is necessary. If the situation seems truly anomalous, contact the Global Support Center.