Parallel Database Extensions (PDE) Message 11914 - 11914 - Analytics Database - Teradata Vantage
Teradata® VantageCloud Lake - Analytics Database Messages
- Edition
- Lake
- Product
- Analytics Database
- Teradata Vantage
- Published
- October 2022
- Language
- English (United States)
- Last Update
- 2024-02-26
- dita:mapPath
- tzr1629746512312.ditamap
- dita:ditavalPath
- ft:empty
- dita:id
- vza1585613049811
- lifecycle
- latest
- Product Category
- Teradata® Vantage™
- Message
- RSS ecountered an anomaly in counting %s; expected %d but found %d.
- Explanation
- During tpa initialization, the Resource Sampling System tallies the storage device list, and subsequently re-traverses the list building an internal table. On this re-traversal, the number of entries of interest had increased; however, RSS was able to handle the increase without error. This usually happens because some function like findit is still adding logical devices while tpainit is running.
- Generated By
- PDE resource usage monitoring.
- For Whom
- System Administrator, System Support Representative.
- Notes
- RSS error messages are normally warnings only, but the calling routine may be coded to terminate after the error message is displayed.
- Remedy
- If the above explanation seems to fit the case, no remedy is necessary. If the situation seems truly anomalous, contact the Global Support Center.