Parallel Database Extensions (PDE) Message 15003 - 15003 - Analytics Database - Teradata Vantage
Teradata® VantageCloud Lake - Analytics Database Messages
- Edition
- Lake
- Product
- Analytics Database
- Teradata Vantage
- Published
- October 2022
- Language
- English (United States)
- Last Update
- 2024-02-26
- dita:mapPath
- tzr1629746512312.ditamap
- dita:ditavalPath
- ft:empty
- dita:id
- vza1585613049811
- lifecycle
- latest
- Product Category
- Teradata® Vantage™
- Message
- AMP Vproc %d has been marked FATAL due to an I/O error.
- Explanation
- The TVS Node Agent has marked the indicated AMP fatal because of a failed device which would potentially need to be accessed by that AMP. This determination is made because the AMP belongs to the same TVS allocation subpool as the failed device. The cause of this device problem must be remedied and a system restart performed before the AMP may be brought back online. Please check other events to get all AMP Vprocs, which are marked FATAL.
- Generated By
- TVS Node Agent
- For Whom
- Field Engineer
- Notes
- None
- Remedy
- The failed device will be shown in a previous event log. Fix the problem that caused the device failure event, then use vprocmanager to bring the fatal AMP back online.