Message
Pdisk device %d is mapped to more than one pdisk %s
Explanation
There is an error in vconfig that is causing the same physical device to be mapped to more than one pdisk. This could be a simple typographical error in the vconfig, or it could be caused by incorrect entries in the system's device directory (different names aliased to the same physical device). It could also be caused by local disk name collisions in different nodes which should be in different cliques but are mistakenly in the same clique. Because of the ambiguities inherent in this error, it is regarded as fatal.
Generated By
TVS Node Agent
For Whom
Field Engineer
Notes
None
Remedy
Contact the Global Support Center.