Parallel Database Extensions (PDE) Message 15068 - 15068 - Analytics Database - Teradata Vantage

Teradata® VantageCloud Lake - Analytics Database Messages

Edition
Lake
Product
Analytics Database
Teradata Vantage
Published
October 2022
Language
English (United States)
Last Update
2024-02-26
dita:mapPath
tzr1629746512312.ditamap
dita:ditavalPath
ft:empty
dita:id
vza1585613049811
lifecycle
latest
Product Category
Teradata® Vantage™
Message
Name of PDISK %d is too long
Explanation
The name given for this pdisk in the vconfig GDO is causing an internal data structure to overflow. Because of this, the pdisk will be marked as inaccessible. This error must be corrected before the device will be used. This may affect one or more AMPs if there is a potential for those AMPs to have data on this device. Please check other events to get all PDISKs, whose names are long.
Generated By
TVS Node Agent
For Whom
Field Engineer
Notes
None
Remedy
Edit the vconfig, use a shorter name for the pdisk, and regenerate the vconfig GDO. If it is not possible to use a shorter name, contact the Global Support Center.