Parallel Database Extensions (PDE) Message 15070 - 15070 - Analytics Database - Teradata Vantage
Teradata® VantageCloud Lake - Analytics Database Messages
- Edition
- Lake
- Product
- Analytics Database
- Teradata Vantage
- Published
- October 2022
- Language
- English (United States)
- Last Update
- 2024-02-26
- dita:mapPath
- tzr1629746512312.ditamap
- dita:ditavalPath
- ft:empty
- dita:id
- vza1585613049811
- lifecycle
- latest
- Product Category
- Teradata® Vantage™
- Message
- PDISK %d has incorrect device number %d in its tag
- Explanation
- A mismatch was detected between this pdisk's global device number as given in the vconfig GDO, and the disk's actual global device number from its device tag. This is likely the result of a cabling error although it could be the result of adding disks to the system without following the recommended procedures. Because of this error, the pdisk will be marked as inaccessible. This error must be corrected before the device will be used. This may affect one or more AMPs if there is a potential for those AMPs to have data on this device. Please check other events to get all PDISKs, which have incorrect device number.
- Generated By
- TVS Node Agent
- For Whom
- Field Engineer
- Notes
- None
- Remedy
- Depending upon the reason, you must fix the cabling, or use proper procedures to add storage devices to the system.