Summarize requests for all users into the following subsecond intervals set in DBQLSummaryTbl:
  • 0 - 0.05 seconds
  • 0.05 - 0.50 seconds
  • 0.50 - 1.00 seconds
  •  > 1 second

Quantify requests in the subsecond range:

BEGIN QUERY LOGGING LIMIT SUMMARY=5,50,100 ELAPSEDTIME ON ALL;