A data block is a disk-resident structure that contains one or more rows from the same table and is the smallest I/O unit for the Teradata Database file system. Data blocks are stored in physical disk sectors or segments, which are grouped in cylinders.

Teradata Database employs Cylinder Read to enable full-file scan operations to run more efficiently by reading a list of cylinder-resident data blocks with a single I/O operation. This reduces I/O overhead from once per data block to once per cylinder. This can significantly reduce the time it takes to do a full-table scan of large tables. During installation, Cylinder Read is enabled by default.

If you notice a performance hit from Cylinder Read, try decreasing the value of the Cylinder Read Aging Threshold control field in the Ctl DBS screen. For information on this field, see Teradata Vantage™ - Database Utilities , B035-1102 .
Cylinder Read may improve performance during operations such as:
  • Full-table scan operations under conditions such as:
    • Large select
    • Merge INSERT ... SELECT
    • Merge delete
    • Sum, average, minimum, maximum, and count aggregates
  • Joins operations that involve many data blocks, such as merge or product joins.

Cylinder reads are not invoked when there is row partitioning elimination or column partitioning elimination.