When Multiple Nodes Fail | Teradata Vantage on Azure (DIY) - When Multiple Nodes Fail - Teradata Vantage on Azure

Teradata Vantageā„¢ on Azure (DIY) Installation and Administration Guide

Product
Teradata Vantage on Azure
Release Number
8.0
Published
March 2021
Language
English (United States)
Last Update
2021-04-01
dita:mapPath
ohu1564530491656.ditamap
dita:ditavalPath
quw1564586883304.ditaval
dita:id
B035-2810
Product Category
Cloud

When two or more nodes fail at the same time, the nodes can be replaced at the same time as long as one node remains running to act as the node failure recovery control node. However, the database stops if both BYNET relay nodes in the database are unavailable during node failure recovery. The database stops if one or more replacement VMs cannot spin up.

If two or more nodes fail at different times while node failure recovery is in progress, contact Teradata Services.