You can set state-specific limits for Meters to override the default limit for a state. For example, to raise the limit of a Meter during a low-traffic state, lower the limit during a high-traffic state.

  1. Edit or Create a ruleset.
  2. From the ruleset toolbar, select Meters.
  3. Select a Meter or create one.
  4. Click the State Specific Settings tab.
  5. Under Default Settings, do one of the following:
    Limit Description
    Unlimited Under Limit, select Unlimited.
    Limited Under Limited, enter the limit, select the time unit from the drop-down box and then select Delay or Reject.
  6. [Optional] To override the default settings for a state do the following:
    1. Next to a state name, click
    2. Select Create State Specific Settings
    3. If you do not want to limit the queries for this state, select Unlimited under Limit.
    4. To limit the queries for this state, enter a limit number in the box, select the time unit from the drop-down, and select either Delay or Reject.