REPLACE MACRO SystemFE.MiniCylPacks
 (Fromdate (date,               FORMAT 'YYYY-MM-DD'),
  Todate   (date, DEFAULT DATE, FORMAT 'YYYY-MM-DD')) AS
(
echo 'set defaults;';
echo 'set format on;';
echo 'set width 80;';
echo 'set NULL as "-";';
echo 'set separator 2;';
echo 'set pagelength 60;';
echo 'set suppress on 3,4;';
echo 'set omit on 1,2;';
echo 'set heading "&DATE||MiniCylPacks Performed Between &1 and &2||&TIME"
;';
Select    :Fromdate      (Format 'YYYY-MM-DD')
        , :Todate        (Format 'YYYY-MM-DD')
        , VProc
        , TheDate        (Title 'Date')
        , TheTime        (Title 'Time')
        , Event_Tag      (Title 'Event')
From    DBC.Software_Event_Log
Where   Event_Tag in (0340514100, 0340514200, 0340514300)
And     Line=1
And     DBC.Software_Event_Log.TheDate Between :Fromdate and :Todate
With    Count(*) (Title '***** Number of MiniCylPack log messages On vproc &3 =', FORMAT 'zzzz9')
By       3
Order By 3,4,5;
echo 'set defaults;';
);