  1. On the designated-active server, edit the sync.properties file:
    Property Value
    sync.isMaster True
  2. On the designated-standby and standby-only servers, edit the sync.properties file:
    Property Value
    sync.isMaster False
  3. On the Data Mover designated-active repository Postgres configuration, change the wal_level value to logical:
    /var/opt/teradata/postgres/data/postgres.conf: wal_level = logical
  4. Restart the Data Mover repository:
    /etc/init.d/postgresql stop