16.10 - Immediate Qualification - Teradata Workload Management

Teradata Database Workload Management User Guide

prodname
Teradata Workload Management
vrm_release
16.10
created_date
June 2017
category
Administration
User Guide
featnum
B035-1197-161K
With Immediate qualification, once the metric exceeds the specified threshold, TASM activates the event when it is detected on the next event interval check. This is the only qualification available for these event types:
  • Component down events: Node Down, AMP Fatal, PE Fatal, and Gateway Fatal
  • User-defined events
  • Delay queue events (depth and time)

Teradata recommends that you do not use Immediate qualification for any other event types.