Defining SVC Numbers - Teradata Tools and Utilities

Teradata® Tools and Utilities for IBM z/OS Installation Guide

Product
Teradata Tools and Utilities
Release Number
17.00
Published
June 2020
Language
English (United States)
Last Update
2020-06-19
dita:mapPath
gfl1544831938738.ditamap
dita:ditavalPath
dyf1465132352622.ditaval
dita:id
B035-3128
lifecycle
previous
Product Category
Teradata Tools and Utilities
Complete this step only if you have chosen to use SVC communication mode instead of PC (Program Call) mode at your site. In general, the more efficient PC mode is recommended.

If your site is using PC mode, go to Defining Teradata Director Program Subsystems.

If you are using the SVC communication mode:

  1. Define a minimum of one SVC number for use by the Teradata software. To accommodate coexistence of the current version of Vantage software with a future version, Teradata recommends that you define two SVC numbers.

    Each SVC number defined must have all of the following characteristics:

    • Three-digit number, in the range 200-255 inclusive, and currently unassigned.
    • SVC type 3 or type 4.