Purpose
The STATUS DBS Orderby CN command reports the status of Online and NotOnline Teradata Database AMP vprocs ordered by cluster number.
Syntax
{ STATUS | ST } DBS [ ORDERBY CN ]
Usage Notes
The STATUS DBS Orderby CN command returns the Online and NotOnline Teradata Database AMP vprocs ordered by the cluster status tables only. When applicable, a footnote will follow the Database Status Table, indicating which AMP vproc has been selected as the Control AMP.
The following table shows the columns of the ONLINE vproc status row.
Column | Description |
---|---|
Vproc-Ids Range | Uniquely identifies the Vproc-id or Vproc-ids individually or in a range across the entire system. Vproc numbers in the range of 0 through 30719 are used exclusively by the Teradata Database configuration. Vproc numbers greater than 30719 are used exclusively by PDE and are not included in the Teradata Database logical configuration. |
Crash Count | Represents the number of times the vproc has crashed. |
CN No. | Displays the cluster number for the AMP as defined during a system configuration or reconfiguration. The valid range of cluster numbers is 0 to 8099. |
The following table shows the columns of the NOTONLINE vproc status row.
Column | Description |
---|---|
Vproc-Ids Range | Uniquely identifies the Vproc-id or Vproc-ids individually or in a range across the entire system. Vproc numbers in the range of 0 through 30719 are used exclusively by the Teradata Database configuration. Vproc numbers greater than 30719 are used exclusively by PDE and are not included in the Teradata Database logical configuration. |
Crash Count | Represents the number of times the vproc has crashed. |
Vproc State | Represents the current PDE system state of a vproc if the state is not online. |
Config Status | Displays the Teradata Database Logical Configuration Map Status of a vproc. |
Cluster Number | Displays the cluster number for the AMP as defined during a system configuration or reconfiguration. The valid range of cluster numbers is 0 to 8099. |
Example: Displaying a cluster-ordered list of AMP status
Enter a command, HELP or QUIT: status dbs orderby cn SYSTEM NAME: ippd DBS LOGICAL CONFIGURATION ------------------------- ONLINE AMP Vprocs ordered by Cluster No. - Vproc-Ids Crash CN Vproc-Ids Crash CN Range Cnt NO Range Cnt NO -------------------------- --- ---- -------------------------- --- ---- 0*-1 0 0 2-3 0 1 4-5 0 2 6-7 0 3 ------------------------------------------------------------------------------- * DBS Control AMP DBS State: Logons are enabled - Users are logged on DBS RestartKind: COLD