For CPs That Do Not Require the CCU Operand in the START Command - Teradata Director Program

Teradata Director Program Reference

Product
Teradata Director Program
Release Number
15.00
Language
English (United States)
Last Update
2018-09-28
dita:id
B035-2416
lifecycle
previous
Product Category
Teradata Tools and Utilities

For CPs That Do Not Require the CCU Operand in the START Command

The following table lists sense bytes 0 and 1, along with the corresponding device status byte (in hexadecimal) as returned in the CSW for devices of CPs that do not require the CCU operand on the START command:

 

Sense Byte

Status Byte

Description

0

1

 

 

10

01

0E

CIC hardware error

08

05

0E

Bus/Tag in driver fault

80

06

0E

Illegal field id for dev 0

80

07

0E

Message header size error for dev 0

80

08

0E

Message count error for dev 0

80

09

0E

Message size error for dev 0

80

0C

0E

Odd byte xfer for dev 0

80

0D

0E

Input Queue empty for dev 0 write

80

0E

0E

Rewind for dev 0 without a Writekey

80

10

0E

Dev 1 read stopped before all the data was transferred

80

11

0E

Two consecutive dev 0 Writekeys

80

14

0E

Unrecognized command byte during Initial Selection sequence

20

19

0E

Bad parity on Command byte during Initial Selection or following a Write operation

10

28

0D

CP did not respond to CIC interrupt in allotted time (1 second)

00

30

22

IOP Startup byte

00

33

85

The CIC has gone from OFFLINE to ONLINE.

80

39

0E

Write operation exceeded maximum CIC local buffer length

80

43

0E

WriteCount specified a max block size too small for the Teradata Database

80

44

0E

WriteKey block size greater than maximum allowed