17.10 - Maximum Length - Call-Level Interface Version 2

Teradata® Call-Level Interface Version 2 Reference for Workstation-Attached Systems

Product
Call-Level Interface Version 2
Release Number
17.10
Release Date
October 2021
Content Type
Programming Reference
Publication ID
B035-2418-061K
Language
English (United States)

The maximum length (in bytes) needed for the request buffer can be calculated as follows:

maximum Request Buffer Length =
   
   (4 + the maximum length of a request string) +
   (4 + the maximum length of using data,
      including indicator bytes if User Presence
      Bits is set to ‘Y’) +
   (14 if Request Processing Option = P) +
   (6 for overhead)