Manual In-Doubt Resolution - IBM CICS Interface for Teradata

IBM CICS Interface for Teradata® Reference

Product
IBM CICS Interface for Teradata
Release Number
17.00
Published
June 2020
Language
English (United States)
Last Update
2020-06-19
dita:mapPath
xhj1544831946672.ditamap
dita:ditavalPath
obe1474387269547.ditaval
dita:id
B035-2448
Product Category
Teradata Tools and Utilities

Manual in-doubt resolution is necessary when automatic in-doubt resolution is unavailable or unsuccessful.

When the system is restarted, the master console displays a CICS message for each in-doubt unit of recovery.

You can find out about in-doubt sessions or manually resolve them using the following means:
  • The TPCCONS utility on the system console (see Teradata Vantage™ - Database Utilities , B035-1102 ).
  • A CLIv2 application that logs on to the Resolver Base Module and resolves in-doubt sessions using TPCCONS commands described in Teradata Vantage™ - Database Utilities , B035-1102 ).
  • The TDP commands DISPLAY INDOUBT, COMMIT, and ROLLBACK (see Teradata® Director Program Reference, B035-2416).
  • CICS log records for a unit of recovery
  • The Teradata CICS transaction, DSES (see CICS Interface Operation).