17.00 - Manual In-Doubt Resolution - IBM CICS Interface for Teradata

IBM CICS Interface for Teradata® Reference

prodname
IBM CICS Interface for Teradata
vrm_release
17.00
created_date
June 2020
category
Programming Reference
featnum
B035-2448-220K

Manual in-doubt resolution is necessary when automatic in-doubt resolution is unavailable or unsuccessful.

When the system is restarted, the master console displays a CICS message for each in-doubt unit of recovery.

You can find out about in-doubt sessions or manually resolve them using the following means:
  • The TPCCONS utility on the system console (see Teradata Vantage™ - Database Utilities , B035-1102 ).
  • A CLIv2 application that logs on to the Resolver Base Module and resolves in-doubt sessions using TPCCONS commands described in Teradata Vantage™ - Database Utilities , B035-1102 ).
  • The TDP commands DISPLAY INDOUBT, COMMIT, and ROLLBACK (see Teradata® Director Program Reference, B035-2416).
  • CICS log records for a unit of recovery
  • The Teradata CICS transaction, DSES (see CICS Interface Operation).