  1. Open the BAR Setup portlet.
  2. From the DSC Servers list, select your DSC server.
  3. From the Categories list, click General.
  4. Under General System Details, edit or view the following:
    Setting Description
    DSC Server Name View only.

    To change the DSC Server Name, see Changing the DSC Server Name.

    Enable DSC server Check or uncheck as needed.
    Broker IP/Host View only.
    Important: To edit this value, remove and then re-add the DSC Server. Do not edit the value here. See Removing a DSC Server and Adding a DSC Server.
    Broker Port View only.
    Important: To edit this value, remove and then re-add the DSC Server. Do not edit the value here. See Removing a DSC Server and Adding a DSC Server.
    Broker Connectivity View only.

    To switch between TCP and SSL, see Toggling SSL or TCP after Installation.

    DSC Repository Warning Thresholds Maximum amount of data to store in your DSC repository. A repository size below 85% of the threshold is normal for BAR operations. After 85% of the size threshold is met, warning messages are generated. After 95% of the size threshold is met, all BAR jobs that create more data on the repository receive an error message and do not run. At that point, the repository database perm space needs to be increased or jobs must be deleted to continue using DSA.
    After increasing perm space, restart the DSC service so that the change takes effect immediately.
    Security Management Require Teradata Viewpoint authentication on the DSA command-line interface. If checked, a user submitting certain commands from the command-line interface must enter a valid Teradata Viewpoint user name and password.
    BAR Logging Level of BAR log information to display for the Data Stream Controller and the BAR Network Client. Extensive logging information is typically only useful for support personnel when gathering information about a reported problem.
    Error
    Default. Enables minimal logging. Provides only error messages.
    Warning
    Adds warning messages to error message logging.
    Info
    Adds informational messages to warning and error message logging.
    Debug
    Full logging. All messages, including debug, are sent to the job log.
    This setting can affect performance.
    Delete Retired Jobs When a backup job is deleted after being retired in the BAR Operations portlet.
    After
    Number of days from the date a job is retired to wait before deleting the job.
    Never
    Prevents deletion of retired jobs.