Second-Tier Switches | Teradata IntelliFlex 1.x (19-36 Groups) - System Topology for 19 to 36 Groups (36-Port Switches) - BAR Managed Servers - IntelliBase Platforms - IntelliFlex Platforms

Teradata® Hardware Product Guide

Deployment
VantageCore
Edition
IntelliFlex
Product
BAR Managed Servers
IntelliBase Platforms
IntelliFlex Platforms
Published
February 2022
Language
English (United States)
Last Update
2024-01-26
dita:mapPath
kaf1526587423297.ditamap
dita:ditavalPath
exclude_all_interim_filters_FLUTO.ditaval.ditaval
dita:id
kaf1526587423297
Product Category
Hardware
The IntelliFlex system can accommodate up to 36 groups using four pairs of second-tier 36-port switches. This allows for up to 468 nodes.
System Network Topology for a 36-Group IntelliFlex System

  • The system consists of up to 36 groups.
  • The first cabinet contains IntelliFlex processing nodes.
  • The other cabinets may also contain IntelliFlex processing nodes.
  • The first cabinet contains a system VMS for Server Management, and may contain additional TMSs.
  • A cabinet VMS for Server Management is added for every 50 servers.
  • Each clique forms a group of up to 13 nodes. The nodes in the group share the first-tier switches in the first cabinet of the pair.
  • Four ports on each of the first-tier InfiniBand switches in each group are used to provide the uplink connections to the second-tier switches.
  • The system uses four sets of 36-port second-tier switches. These second-tier switches are located in cabinet 2, cabinet 4, cabinet 6, and cabinet 8.
  • Of the four uplink connections to the second-tier switches, one connects to each second-tier switch (for each fabric).
  • When connected to a UDA network, the second-tier switches can be used for UDA connections. Distribute the UDA connections evenly across the pairs of second-tier switches for best performance.